Maintaining the efficiency of your ETC-PH V2 Series units is crucial for ensuring seamless operation in your food service business. At FWEParts, we recognize the importance of keeping your equipment in peak condition. This guide, “How to Replace Hot Air & Water Elements on ETC-PH V2 Series Units,” provides detailed, easy-to-follow steps for replacing both hot air and water elements. With the right tools and parts, you’ll have your unit running optimally in no time. Should you need additional support, our knowledgeable team is ready to assist. Contact us at 1-615-805-3270 or service@fweparts.com for expert advice.

Tools Needed

  • Driver Drill with #2 Phillips Bit
  • 5/16″ Nut Driver
  • 11/16″ Socket Wrench
  • Screwdriver
  • Pliers
  • Heat Tape

Parts Used in this Tutorial

Steps

Replacing Hot Air Element

0:20 | Step 1: Open the unit and remove the heat tunnel assembly exposing the element and blower housing.

0:31 | Step 2: Remove the side panel and locate the element. Disconnect the element connections, take off the nuts and washers, and remove the element by pulling it out of the blower housing. Discard the old element.

1:00 | Step 3: Install the new element through the blower hosing, locking in place with nuts and washers used in Step 2.

1:18 | Step 4: Reconnect the element connections. Restore power and test the unit for operationality.

1:28 | Step 5: Once operationality is confirmed, reinstall the side panel and heat tunnel assembly. Return the unit to service.

Replacing Water Element

1:45 | Step 1: Open the unit and remove the heat tunnel assembly. Remove the water pan from the bottom of the unit.

1:53 | Step 2: Locate the element underneath the water pan and remove the two screws holding the element in place

2:01 | Step 3: Using a screwdriver and pliers if necessary, carefully bend the element clips until the element can be removed from the clips.

2:12 | Step 4: Remove and discard the heat tape if necessary. Pull the element out and remove wire connections from the element terminals. Discard the old elements.

2:26 | Step 5: Install the wire connection onto the new element terminals and insulate with heat tape.

2:33 | Step 6: Push the new element back into place, aligning gasket with back plate. Secure with screws removed in Step 2.

2:44 | Step 7: Reinstall the water pan and fill with water. Restore power and test unit for operationality.

2:52 | Step 8: Once operationality is confirmed, reinstall heat tunnel assembly and return the unit to service.


As we wrap up this guide on replacing hot air and water elements on ETC-PH V2 Series units, we hope the instructions provided have been straightforward and helpful. At FWEParts, our goal is to help you keep your equipment running smoothly, ensuring the success of your food service business. If you need further assistance with this process or have any other questions, our expert team is here to support you. Contact us at 1-615-805-3270 or service@fweparts.com for personalized help. Your success is our priority, and we’re just a call or email away.

Share this post